The Liquid Controls LCR-II registration system delivers consistent, reliable, and accurate metering data. It is designed for use in truck-mounted or fixed-site custody transfer applications worldwide.
Returns & Refunds Policy
Warranty Against Defects
Original Products
Ships Worldwide
Dedicate Support
The Liquid Controls LCR-II registration system delivers consistent, reliable, and accurate metering data. It is designed for use in truck-mounted or fixed-site custody transfer applications worldwide.
Certifications:
US Weights & Measures Approved: LCR-II.
Measurement Canada Approved: LCR-II.
Improved Efficiency: Enhances performance compared to mechanical systems.
Custody Transfer Approvals: Compliant with regulatory standards for accurate custody transfer.
Rugged & Reliable Design: Built to withstand demanding environments.
Simple Operation: User-friendly interface for ease of use.
Mobile Computing Compatibility: Integrates with mobile solutions such as DMS.
Multi-point Calibration: Enhances accuracy across a wide flow range.
Electronic Temperature Volume Compensation (ETVC): Adjusts for temperature variations during deliveries.
Valve Control and Audit Trail: Provides increased security and traceability.
Future Expansion and Modularity: Supports RS232/485 communication for flexible expansion.
Enhanced Delivery System Control: Utilizes two-stage valves and optical air eliminators for precision and reliability.
Repeatability: 0.03% of reading over the entire range.
Linearity:
±0.10% over a 5:1 range from maximum nominal meter capacity.
±0.10% over a 10:1 range from maximum nominal meter capacity.
±0.15% over a 40:1 range from maximum nominal meter capacity.
Calibration: Multi-point calibration with LectroCount™ Electronic Registration ensures superior accuracy.
Electrical and Environmental Specifications:
Power Supply: +9 to 28 VDC, 3A maximum (including solenoid valves).
Operating Temperature Range: -40° to 158°F (-40° to 70°C).
Enclosure Rating: Class 1, Division 2, Group C&D, NEMA 4X.
Input and Output Options:
Temperature Input: 4-Wire Platinum RTD.
Pulse Inputs: +5 to 28 V peak-to-peak, open collector, single channel or quadrature.
Control Valve Outputs (2): Open drain transistor for 2-stage valve control, 1A Max. per channel (12VDC or 24VDC).
Auxiliary Outputs (2): General-purpose auxiliary control outputs.
Aux(1): 1A Max.
Aux(2): 150mA Max.
Scaled Pulse Output: Open drain output, 1A Max.
Optical air eliminators.
Two-stage valves.
Printers (Epson, Okidata, Blaster models).
Remote displays for enhanced visibility and monitoring.