This M30 — 4" LC Meter is designed for measuring liquid flow rates up to 1325 liters per minute (LPM).
Returns & Refunds Policy
Warranty Against Defects
Original Products
Ships Worldwide
Dedicate Support
Meter Classes | Description | Bearing Material |
---|---|---|
1 | Refined petroleum products | Ni-Resist* |
2 | Aviation and jet fuel | Ni-Resist* |
14 | Crude oil | Ni-Resist* |
16 | General solvents | Carbon |
*(carbon bearings are standard on some meter sizes of this class, please consult factory)
M30A1 METER WITH REGISTRATION
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
TEMP. COMP. |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
||||||
M30A1-LCR.iQ-I#1 |
L-R |
LITRES |
BUNA |
N/A |
OIMIL |
|
MECHANICAL REGISTRATION |
||||||
M30A1-MECH-NP#1 |
L-R |
LITRES |
BUNA |
N/A |
NIST |
|
M30A1-MECH-NP#2 |
L-R |
WH GAL |
BUNA |
N/A |
NIST |
|
M30AT1-MECH-NP#1 |
L-R |
WH GAL |
BUNA |
YES |
NIST |
M30C1 METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
STRAINER TYPE |
MESH |
AIR ELIM. |
CHECK VALVE |
TEMP. COMP. |
SOFTWARE |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
|||||||||||
M30C1-LCR.iQ-I#1 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
LCR®-II REGISTRATION |
|||||||||||
M30CY1-LCR2-I#1 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
METAL INLET |
YES |
SL200 ST200 |
NIST |
|
LCR®600 REGISTRATION |
|||||||||||
M30C1-LCR600-I#1 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
SL600 ST600 |
NIST |
|
MECHANICAL REGISTRATION |
|||||||||||
M30C1-MECH-NP#2 |
L-R |
IMP GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M30C1-MECH-NP#3 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M30C1-MECH-NP#4 |
L-R |
DEKALITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
OIML |
|
M30C1-MECH-NP#5 |
L-R |
LITRES |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
CAN |
|
M30C1-MECH-NP#6 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M30C1-MECH-NP#9 |
L-R |
LITERS |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
SET UP FOR ELECTRONICS |
|||||||||||
M30C1-SUFE#1 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
|
M30C1-SUFE#2* |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
*INCLUDES METAL INLET CHECK
M30G1 METER WITH REGISTER + PRINTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
PRESET TYPE |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
W&M APPROVAL |
MECHANICAL REGISTRATION |
||||||||||
M30G1-MECH-NP#2 |
L-R |
WH GAL |
BUNA |
STD |
40 |
MECH |
N/A |
N/A |
N/A |
NIST |
M30K1
METER WITH REGISTER + PRESET VALVE + PRESET + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
PRESET TYPE |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||||
M30K1-MECH-NP#2 |
L-R |
IMP GAL |
BUNA |
5-DIGIT |
MECH |
REAR |
STD |
40 |
MECH |
OIML |
|
M30K1-MECH-NP#4 |
L-R |
LITRES |
VITON® |
5-DIGIT |
MECH |
REAR |
STD |
40 |
MECH |
OIML |
|
M30K1-MECH-NP#8 |
L-R |
LITRES |
BUNA |
5-DIGIT |
MECH |
REAR |
STD |
40 |
MECH |
NIST |
M30P1
METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M30P1-LRG#1 |
L-R |
LITRES |
VITON® |
OIML |
|
M30P1-LRG#2 |
L-R |
WH GAL |
VITON® |
NIST |
|
M30P1-LRG#3 |
L-R |
LITRES |
VITON® |
CAN |
|
M30P1-LRG#4 |
L-R |
WH GAL |
BUNA |
NIST |
|
M30P1-LRG#5 |
L-R |
LITRES |
BUNA |
CAN |
M30S1
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M30S1-POD#1 |
L-R |
WH GAL |
BUNA |
NIST |
|
M30S1-POD#2 |
L-R |
LITRES |
BUNA |
CAN |
|
M30S1-POD#3 |
L-R |
LITRES |
VITON® |
CAN |
M30A2 M30 METER WITH REGISTER
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
TEMP COMP. |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
||||||
M30A2-LCR.IQ-I#1 |
L-R |
150 |
WH GAL |
N |
NIST |
|
MECHANICAL REGISTRATION |
||||||
M30A2-MECH-NP#2 |
L-R |
150 |
WH GAL |
N |
NIST |
|
M30A2-MECH-NP#5*** |
L-R |
150 |
DEKALITRES |
N |
OIML |
|
M30AT2-MECH-NP#1 |
R-L |
150 |
WH GAL |
Y |
NIST |
|
M30AT2-MECH-NP#2 |
L-R |
150 |
WH GAL |
Y |
NIST |
|
M30AT2-MECH-NP#3 |
L-R |
150 |
LITRES |
Y |
NIST |
|
M30AT2-MECH-NP#4 |
R-L |
150 |
LITRES |
Y |
NIST |
|
M30AT2-MECH-WP#2** |
R-L |
150 |
WH GAL |
Y |
NIST |
**PROVIDED WITH 100 PPR SOLID STATE PULSER
***VITON® ELASTOMERS
M30C2 M30 METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
STRAINER TYPE |
MESH |
AIR ELIM. |
TEMP COMP. |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||
M30CT2-MECH-NP#1 |
L-R |
150 |
LITRES |
STD |
40 |
MECH |
Y |
OIML |
|
M30C2-MECH-NP#1 |
L-R |
150 |
WH GAL |
STD |
40 |
MECH |
N |
NIST |
M30P2
M30 METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M30P2-LRG#1 |
L-R |
150 |
WH GAL |
NIST |
M30S2
M30 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M30S2-POD#1 |
L-R |
150 |
LITRES |
CAN |
M40A2
METER WITH REGISTERATION
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
TEMP COMP. |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
||||||
M40A2-LCR.IQ-I#1 |
L-R |
150 |
WH GAL |
N |
NIST |
|
M40A2-LCR.IQ-E#1* |
L-R |
150 |
LITRES |
N |
OIML |
|
M40AT2-LCR.IQ-I#1 |
L-R |
150 |
WH GAL |
Y |
NIST |
|
MECHANICAL REGISTRATION |
||||||
M40A2-MECH-NP#1 |
L-R |
150 |
WH GAL |
N |
NIST |
|
M40AT2-MECH-NP#1 |
L-R |
150 |
WH GAL |
Y |
NIST |
|
SETUP FOR ELECTRONIC REGISTRATION |
||||||
M40A2-SUFE#1 |
L-R |
150 |
WH GAL |
N |
NIST |
M40C2 METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
STRAINER TYPE |
MESH |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||
M40C2-MECH-NP#1 |
L-R |
150 |
WH GAL |
STD |
40 |
NIST |
M40E2 METER WITH REGISTER + PRINTER
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
MESH |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
||||||
M40E2-MECH-NP#1 |
L-R |
150 |
WH GAL |
N |
NIST |
M40P2 METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M40P2-LRG#2 |
L-R |
150 |
WH GAL |
NIST |
M40S2 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M40S2-POD#1 |
L-R |
150 |
WH GAL |
NIST |
M30A14
METER WITH REGISTER
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
|
LCR.iQ® REGISTRATION |
||||
M30A14-MECH-NP#1 |
L-R |
WH. GAL |
VITON |
|
M30A14-MECH-NP#2 |
L-R |
DEKALITRES |
VITON |
M30C14
METER WITH REGISTER + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
STRAINER TYPE |
MESH |
AIR ELIM. |
|
MECHANICAL REGISTRATION |
|||||||
M30C14-MECH-NP#1* |
L-R |
WH. GAL |
VITON |
STANDARD |
40 |
MECH |
|
M30C14-MECH-NP#2* |
L-R |
LITRES |
VITON |
STANDARD |
20 |
MECH |
*SUPPLIED WITH 1-FOOT HEAT EXTENSION
M30P14
METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
|
LESS REGISTER & GEAR PLATE |
||||
M30P14-LRG#1 |
L-R |
WH. GAL |
VITON |
M30S14
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
|
POD (PULSE OUTPUT DEVICE) |
||||
M30S14-POD#1 |
L-R |
WH. GAL |
VITON |
M30K16
METER WITH REGISTER + PRESET VALVE + PRESET + STRAINER + AIR ELIMINATOR
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
PRESET |
VALVE TYPE |
VALVE OUTLET |
STRAINER TYPE |
MESH |
AIR ELIM. |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
|||||||||||
M30K16-MECH-NP#1 |
L-R |
LITRES |
PTFE |
5-DIGIT |
MECH |
FRONT |
STD |
40 |
MECH |
NIST |
|
M30S16
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M30S16-POD#1 |
L-R |
LITRES |
PTFE |
OIML |
|
To find the maximum meter flow rate in relation to the meter bearing material and product viscosity, use the chart below:
You are outside of the permitted pressure loss for the designated meter and bearing if the plotted point is higher than the bearing material slope. Either use a larger meter, lower the flow rate, or think about using other bearing materials.
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Mollitia iste laborum ad impedit pariatur esse optio tempora sint ullam autem deleniti nam in quos qui nemo ipsum numquam, reiciendis maiores quidem aperiam, rerum vel recusandae