Shopping Cart

Subtotal: $170.00

Wishlist

Liquid Controls M30 - 4" LC Meter (1325 LPM)

This M30 — 4" LC Meter is designed for measuring liquid flow rates up to 1325 liters per minute (LPM).

CATEGORY: Flow Meters
TYPE: Equipment

Returns & Refunds Policy

Warranty Against Defects

Original Products

Ships Worldwide

Dedicate Support

 

Meter Classes Description Bearing Material
Refined petroleum products Ni-Resist*
2 Aviation and jet fuel Ni-Resist*
14 Crude oil Ni-Resist*
16 General solvents Carbon

*(carbon bearings are standard on some meter sizes of this class, please consult factory)

  • Flow Capacity: 1325 Liters Per Minute (LPM).
  • Pressure Rating:
    • Maximum Pressure: 150 psi (10.3 bar or 1034 kPa).
  • Flange Size: 4 inches.
  • Material: Constructed from aluminum for durability and lightweight performance.
  • Seal Options: Available with Buna or Viton® seals, depending on the catalog number for compatibility with different fluids.
  • Operating Temperature Range: -40°F to 185°F (-40°C to 85°C).
  • Bearing Material:
    • Recommended Material: Ni-Resist bearings for enhanced durability and corrosion resistance.
    • Alternative Material: Carbon bearings may be standard in some meter sizes—consult the factory for details.

M30A1 METER WITH REGISTRATION

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEALS

TEMP. COMP.

W&M APPROVAL

LCR.iQ® REGISTRATION

M30A1-LCR.iQ-I#1

L-R

LITRES

BUNA

N/A

OIMIL

MECHANICAL REGISTRATION

M30A1-MECH-NP#1

L-R

LITRES

BUNA

N/A

NIST

 

M30A1-MECH-NP#2

L-R

WH GAL

BUNA

N/A

NIST

M30AT1-MECH-NP#1

L-R

WH GAL

BUNA

YES

NIST

M30C1 METER WITH REGISTER + STRAINER + AIR ELIMINATOR

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEALS

STRAINER TYPE

MESH

AIR ELIM.

CHECK VALVE

TEMP. COMP.

SOFTWARE

W&M APPROVAL

LCR.iQ® REGISTRATION

M30C1-LCR.iQ-I#1

L-R

LITRES

BUNA

STD

40

MECH

N/A

N/A

N/A

NIST

LCR®-II REGISTRATION

M30CY1-LCR2-I#1

L-R

WH GAL

BUNA

STD

40

MECH

METAL INLET

YES

SL200 ST200

NIST

LCR®600 REGISTRATION

M30C1-LCR600-I#1

L-R

WH GAL

BUNA

STD

40

MECH

N/A

N/A

SL600 ST600

NIST

MECHANICAL REGISTRATION

M30C1-MECH-NP#2

L-R

IMP GAL

BUNA

STD

40

MECH

N/A

N/A

N/A

OIML

 

M30C1-MECH-NP#3

L-R

LITRES

BUNA

STD

40

MECH

N/A

N/A

N/A

OIML

M30C1-MECH-NP#4

L-R

DEKALITRES

BUNA

STD

40

MECH

N/A

N/A

N/A

OIML

M30C1-MECH-NP#5

L-R

LITRES

BUNA

STD

40

MECH

N/A

N/A

N/A

CAN

M30C1-MECH-NP#6

L-R

WH GAL

BUNA

STD

40

MECH

N/A

N/A

N/A

NIST

M30C1-MECH-NP#9

L-R

LITERS

BUNA

STD

40

MECH

N/A

N/A

N/A

NIST

SET UP FOR ELECTRONICS

M30C1-SUFE#1

L-R

WH GAL

BUNA

STD

40

MECH

N/A

N/A

N/A

NIST

 

M30C1-SUFE#2*

L-R

WH GAL

BUNA

STD

40

MECH

N/A

N/A

N/A

NIST

*INCLUDES METAL INLET CHECK

M30G1 METER WITH REGISTER + PRINTER + STRAINER + AIR ELIMINATOR

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEALS

PRESET TYPE

VALVE TYPE

VALVE OUTLET

STRAINER TYPE

MESH

AIR ELIM.

W&M APPROVAL

MECHANICAL REGISTRATION

M30G1-MECH-NP#2

L-R

WH GAL

BUNA

STD

40

MECH

N/A

N/A

N/A

NIST

M30K1

METER WITH REGISTER + PRESET VALVE + PRESET + STRAINER + AIR ELIMINATOR

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEALS

PRESET TYPE

VALVE TYPE

VALVE OUTLET

STRAINER TYPE

MESH

AIR ELIM.

W&M APPROVAL

MECHANICAL REGISTRATION

M30K1-MECH-NP#2

L-R

IMP GAL

BUNA

5-DIGIT

MECH

REAR

STD

40

MECH

OIML

 

M30K1-MECH-NP#4

L-R

LITRES

VITON®

5-DIGIT

MECH

REAR

STD

40

MECH

OIML

M30K1-MECH-NP#8

L-R

LITRES

BUNA

5-DIGIT

MECH

REAR

STD

40

MECH

NIST

M30P1

METER LESS REGISTER AND GEAR PLATE

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEALS

W&M APPROVAL

LESS REGISTER AND GEAR PLATE

 

M30P1-LRG#1

L-R

LITRES

VITON®

OIML

 

M30P1-LRG#2

L-R

WH GAL

VITON®

NIST

M30P1-LRG#3

L-R

LITRES

VITON®

CAN

M30P1-LRG#4

L-R

WH GAL

BUNA

NIST

M30P1-LRG#5

L-R

LITRES

BUNA

CAN

M30S1

METER WITH POD (PULSE OUTPUT DEVICE)

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEALS

W&M APPROVAL

POD (PULSE OUTPUT DEVICE)

 

M30S1-POD#1

L-R

WH GAL

BUNA

NIST

 

M30S1-POD#2

L-R

LITRES

BUNA

CAN

M30S1-POD#3

L-R

LITRES

VITON®

CAN

 

M30A2 M30 METER WITH REGISTER

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

TEMP COMP.

W&M APPROVAL

LCR.iQ® REGISTRATION

M30A2-LCR.IQ-I#1

L-R

150

WH GAL

N

NIST

MECHANICAL REGISTRATION

M30A2-MECH-NP#2

L-R

150

WH GAL

N

NIST

 

M30A2-MECH-NP#5***

L-R

150

DEKALITRES

N

OIML

M30AT2-MECH-NP#1

R-L

150

WH GAL

Y

NIST

M30AT2-MECH-NP#2

L-R

150

WH GAL

Y

NIST

M30AT2-MECH-NP#3

L-R

150

LITRES

Y

NIST

M30AT2-MECH-NP#4

R-L

150

LITRES

Y

NIST

M30AT2-MECH-WP#2**

R-L

150

WH GAL

Y

NIST

**PROVIDED WITH 100 PPR SOLID STATE PULSER

***VITON® ELASTOMERS

M30C2 M30 METER WITH REGISTER + STRAINER + AIR ELIMINATOR

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

STRAINER TYPE

MESH

AIR ELIM.

TEMP COMP.

W&M APPROVAL

MECHANICAL REGISTRATION

M30CT2-MECH-NP#1

L-R

150

LITRES

STD

40

MECH

Y

OIML

 

M30C2-MECH-NP#1

L-R

150

WH GAL

STD

40

MECH

N

NIST

M30P2

M30 METER LESS REGISTER AND GEAR PLATE

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

W&M APPROVAL

LESS REGISTER AND GEAR PLATE

M30P2-LRG#1

L-R

150

WH GAL

NIST

 

M30S2

M30 METER WITH POD (PULSE OUTPUT DEVICE)

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

W&M APPROVAL

POD (PULSE OUTPUT DEVICE)

M30S2-POD#1

L-R

150

LITRES

CAN

 

M40A2

METER WITH REGISTERATION

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

TEMP COMP.

W&M APPROVAL

LCR.iQ® REGISTRATION

M40A2-LCR.IQ-I#1

L-R

150

WH GAL

N

NIST

 

M40A2-LCR.IQ-E#1*

L-R

150

LITRES

N

OIML

M40AT2-LCR.IQ-I#1

L-R

150

WH GAL

Y

NIST

MECHANICAL REGISTRATION

M40A2-MECH-NP#1

L-R

150

WH GAL

N

NIST

 

M40AT2-MECH-NP#1

L-R

150

WH GAL

Y

NIST

SETUP FOR ELECTRONIC REGISTRATION

M40A2-SUFE#1

L-R

150

WH GAL

N

NIST

 

M40C2 METER WITH REGISTER + STRAINER + AIR ELIMINATOR

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

STRAINER TYPE

MESH

W&M APPROVAL

MECHANICAL REGISTRATION

M40C2-MECH-NP#1

L-R

150

WH GAL

STD

40

NIST

 

M40E2 METER WITH REGISTER + PRINTER

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

MESH

W&M APPROVAL

MECHANICAL REGISTRATION

M40E2-MECH-NP#1

L-R

150

WH GAL

N

NIST

 

M40P2 METER LESS REGISTER AND GEAR PLATE

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

W&M APPROVAL

LESS REGISTER AND GEAR PLATE

M40P2-LRG#2

L-R

150

WH GAL

NIST

 

M40S2 METER WITH POD (PULSE OUTPUT DEVICE)

CATALOG NUMBER

FLOW

PRESSURE

UNIT OF MEASURE

W&M APPROVAL

POD (PULSE OUTPUT DEVICE)

M40S2-POD#1

L-R

150

WH GAL

NIST

 

 

M30A14

METER WITH REGISTER

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEAL

LCR.iQ® REGISTRATION

M30A14-MECH-NP#1

L-R

WH. GAL

VITON

 

M30A14-MECH-NP#2

L-R

DEKALITRES

VITON

M30C14

METER WITH REGISTER + STRAINER + AIR ELIMINATOR

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEAL

STRAINER TYPE

MESH

AIR ELIM.

MECHANICAL REGISTRATION

M30C14-MECH-NP#1*

L-R

WH. GAL

VITON

STANDARD

40

MECH

 

M30C14-MECH-NP#2*

L-R

LITRES

VITON

STANDARD

20

MECH

*SUPPLIED WITH 1-FOOT HEAT EXTENSION

M30P14

METER LESS REGISTER AND GEAR PLATE

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEAL

LESS REGISTER & GEAR PLATE

M30P14-LRG#1

L-R

WH. GAL

VITON

 

M30S14

METER WITH POD (PULSE OUTPUT DEVICE)

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEAL

POD (PULSE OUTPUT DEVICE)

M30S14-POD#1

L-R

WH. GAL

VITON

 

 

M30K16

METER WITH REGISTER + PRESET VALVE + PRESET + STRAINER + AIR ELIMINATOR

 

CATALOG NUMBER

 

FLOW

UNIT OF MEASURE

 

SEALS

 

PRESET

VALVE TYPE

VALVE OUTLET

STRAINER TYPE

 

MESH

AIR ELIM.

W&M APPROVAL

 

MECHANICAL REGISTRATION

M30K16-MECH-NP#1

L-R

LITRES

PTFE

5-DIGIT

MECH

FRONT

STD

40

MECH

NIST

 

 

M30S16

METER WITH POD (PULSE OUTPUT DEVICE)

CATALOG NUMBER

FLOW

UNIT OF MEASURE

SEALS

W&M APPROVAL

 

POD (PULSE OUTPUT DEVICE)

M30S16-POD#1

L-R

LITRES

PTFE

OIML

 

 

To find the maximum meter flow rate in relation to the meter bearing material and product viscosity, use the chart below:

  • Calculate the percentage of rated capacity that the meter must function at;
  • Calculate the viscosity of the product at the operating temperature of the system.
  • Plot the intersection of the two lines on the chart.
  • Find the appropriate slope on the chart by identifying the meter-bearing material from the construction/application table above.


You are outside of the permitted pressure loss for the designated meter and bearing if the plotted point is higher than the bearing material slope. Either use a larger meter, lower the flow rate, or think about using other bearing materials.