This M60 — 6" LC Meter is designed for measuring liquid flow rates up to 2800 liters per minute (LPM).
Returns & Refunds Policy
Warranty Against Defects
Original Products
Ships Worldwide
Dedicate Support
Meter Classes | Description | Bearing Material |
---|---|---|
1 | Refined petroleum products | Carbon |
2 | Aviation and jet fuel | Carbon |
Flow Rate:
Pressure Rating:
Flange Size:
Material Construction:
Seal Options:
Maximum Pressure:
Temperature Range:
M60A1 METER WITH REGISTRATION |
|||||||
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
TEMP. COMP. |
SOFTWARE |
W&M APPROVAL |
|
LCR.iQ® REGISTRATION |
|||||||
M60A1-LCR.IQ-I#1 |
L-R |
LITRES |
BUNA |
N/A |
N/A |
NIST |
|
LCR®-II REGISTRATION |
|||||||
M60A1-LCR2-I#2 |
L-R |
WH GAL |
BUNA |
N/A |
SL200 ST202 |
NIST |
|
MECHANICAL REGISTRATION |
|||||||
M60A1-MECH-NP#1 |
L-R |
WH GAL |
BUNA |
N/A |
N/A |
NIST |
|
M60A1-MECH-NP#2 |
L-R |
DEKALITRES |
BUNA |
N/A |
N/A |
NIST |
|
M60A1-MECH-NP#4 |
L-R |
DEKALITRES |
BUNA |
N/A |
N/A |
OIML |
|
M60AT1-MECH-NP#1 |
R-L |
WH GAL |
BUNA |
YES |
N/A |
NIST |
M60P1
METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
M60P1-LRG#1 |
L-R |
DEKALITRES |
VITON® |
OIML |
|
M60P1-LRG#2 |
L-R |
WH GAL |
VITON® |
NIST |
M60S1
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
M60S1-POD#1 |
L-R |
WH GAL |
VITON® |
NIST |
|
M60S1-POD#2 |
L-R |
LITRES |
VITON® |
CAN |
|
M60S1-POD#3 |
L-R |
WH GAL |
BUNA |
NIST |
M60A2
METER WITH REGISTER
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
PORT ORIENTATION |
TEMP COMP. |
SOFTWARE |
W&M APPROVAL |
|
LCR.iQ®REGISTRATION |
||||||||
M60A2-LCR.IQ#1 |
L-R |
275 |
WH GAL |
LOW |
N |
N/A |
NIST |
|
M60AT2-LCR.IQ#1 |
L-R |
275 |
LITERS |
LOW |
Y |
N/A |
OIML |
|
LCR®600 REGISTRATION |
||||||||
M60AT2-LCR600-I#1 |
L-R |
275 |
WH GAL |
LOW |
Y |
SL600 ST600 |
NIST |
|
MECHANICAL REGISTRATION |
||||||||
M60A2-MECH-NP#1 |
L-R |
275 |
WH GAL |
LOW |
N |
N/A |
NIST |
|
M60A2-MECH-NP#2 |
L-R |
275 |
DEKALITRES |
LOW |
N |
N/A |
OIML |
|
M60AT2-MECH-NP#1 |
L-R |
275 |
WH GAL |
LOW |
Y |
N/A |
NIST |
|
M60AT2-MECH-NP#2 |
R-L |
275 |
WH GAL |
LOW |
Y |
N/A |
NIST |
|
M60AT2-MECH-NP#4 |
R-L |
275 |
WH GAL |
HIGH |
Y |
N/A |
NIST |
|
M60AT2-MECH-WP#2* |
L-R |
275 |
WH GAL |
LOW |
Y |
N/A |
NIST |
|
M60AT2-MECH-WP#5** |
L-R |
275 |
WH GAL |
LOW |
Y |
N/A |
NIST |
|
SETUP FOR ELECTRONIC REGISTRATION |
||||||||
M60A2-SUFE#1*** |
R-L |
150 |
WH GAL |
HIGH |
N |
N/A |
NIST |
*PROVIDED WITH 10 PPR DRY REED PULSER
**PROVIDED WITH 100 PPR SOLID STATE PULSER
***VITON® ELASTOMERS
M60P2 METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
PORT ORIENTATION |
TEMP COMP. |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||||
M60P2-LRG#1 |
L-R |
150 |
DEKALITRES |
LOW |
N/A |
OIML |
|
M60P2-LRG#2 |
L-R |
150 |
WH GAL |
HIGH |
N/A |
NIST |
M60S2 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
PORT ORIENTATION |
TEMP COMP. |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||||
M60S2-POD#1 |
L-R |
150 |
DEKALITRES |
LOW |
N |
NIST |
|
M60S2-POD#2 |
L-R |
150 |
LITRES |
LOW |
N |
OIML |
To find the maximum meter flow rate in relation to the meter bearing material and product viscosity, use the chart below:
You are outside of the permitted pressure loss for the designated meter and bearing if the plotted point is higher than the bearing material slope. Either use a larger meter, lower the flow rate, or think about using other bearing materials.