This MSAA75 — 4" LC Meter is designed for measuring liquid flow rates up to 2650 liters per minute (LPM).
Returns & Refunds Policy
Warranty Against Defects
Original Products
Ships Worldwide
Dedicate Support
Meter Classes | Description | Bearing Material |
---|---|---|
Class 1 | Refined petroleum products | *Ni-Resist |
Class 14 | Crude oil | *Ni-Resist |
Class 16 | Alternative fuels and solvents | Carbon |
*carbon bearings are standard on some meter sizes of this class, please consult factory.
MSAA75A1 METER WITH REGISTRATION
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
TEMP. COMP. |
W&M APPROVAL |
|
MECHANICAL REGISTRATION |
||||||
MSAA75A1-MECH-NP#1 |
L-R |
DEKALITRES |
BUNA |
N/A |
OIML |
|
MSAA75A1-MECH-NP#2 |
L-R |
WH GAL |
VITON® |
N/A |
NIST |
|
MSAA75A1-MECH-WP#2* |
R-L |
WH GAL |
BUNA |
N/A |
NIST |
|
MSAA75AT1-MECH-WP#1** |
L-R |
DEKALITRES |
VITON® |
YES |
OIML |
*1000PPR PHOTOELECTRIC PULSER
**10PPR DRY REED PULSER
MSAA75S1 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
MSAA75S1-POD#1 |
L-R |
DEKALITRES |
BUNA |
OIML |
|
MSAA75S1-POD#2 |
L-R |
WH GAL |
VITON® |
NIST |
MSAA75A2 METER WITH REGISTER
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
TEMP COMP. |
SOFTWARE |
W&M APPROVAL |
|
LCR®-II REGISTRATION |
|||||||
MSAA75AT2-LCR2-I#1 (CL1, DIV1) |
L-R |
285 |
WH GAL |
Y |
SL200 ST200 |
NIST |
|
MSAA75AT2-LCR2-I#2 (CL1, DIV1) |
R-L |
285 |
WH GAL |
Y |
SL200 ST200 |
NIST |
|
MECHANICAL REGISTRATION |
|||||||
MSAA75AT2-MECH-NP#1 |
R-L |
285 |
WH GAL |
Y |
N/A |
NIST |
MSAA75P2 METER LESS REGISTER AND GEAR PLATE
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
LESS REGISTER AND GEAR PLATE |
|||||
MSAA75P2-LRG#1 |
L-R |
285 |
WH GAL |
NIST |
|
MSAA75P2-LRG#2 |
R-L |
275 |
WH GAL |
NIST |
MSAA75S2 METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
PRESSURE |
UNIT OF MEASURE |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
MSAA75S2-POD#1 |
L-R |
285 |
WH GAL |
NIST |
MSAA75A14
METER WITH REGISTER WITH 4”, 150# ANSI RF FLANGE
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEAL |
|
MECHANICAL REGISTRATION |
||||
MSAA75A14-MECH-NP#1 |
L-R |
WH. GAL |
VITON |
MSAA75S16
METER WITH POD (PULSE OUTPUT DEVICE)
CATALOG NUMBER |
FLOW |
UNIT OF MEASURE |
SEALS |
W&M APPROVAL |
|
POD (PULSE OUTPUT DEVICE) |
|||||
MSAA75S16-POD#1 |
L-R |
LITRES |
VITON® |
NIST |
|
MSAA75S16-POD#1 |
L-R |
LITRES |
VITON® |
CAN |
To find the maximum meter flow rate in relation to the meter bearing material and product viscosity, use the chart below:
You are outside of the permitted pressure loss for the designated meter and bearing if the plotted point is higher than the bearing material slope. Either use a larger meter, lower the flow rate, or think about using other bearing materials.
Flow Rate (LPM):
Pressure Rating:
Flange Size:
Construction Material:
Seals:
Maximum Pressure (again):
Temperature Range:
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Mollitia iste laborum ad impedit pariatur esse optio tempora sint ullam autem deleniti nam in quos qui nemo ipsum numquam, reiciendis maiores quidem aperiam, rerum vel recusandae