The Nitto Seiko Food Flow Meter is specifically designed for applications in the food industry, where hygiene, accuracy, and ease of maintenance are of paramount importance
Returns & Refunds Policy
Warranty Against Defects
Original Products
Ships Worldwide
Dedicate Support
Nitto Seiko Food Flow Meter is a reliable, hygienic, and highly precise solution for the food and beverage industry, where maintaining the quality and safety of the product is critical. Its easy-to-clean structure, durable materials, and versatility make it a preferred choice for many food processing applications.
Rotary Piston Design:
Sanitation and Maintenance:
Material Construction:
Plastic Rotor:
Customizable Counting Units:
Versatility in Applications:
Nominal size symbol |
025 |
040 |
050 |
065 |
080 |
Measured fluid |
Food liquids |
||||
Nominal size |
25A |
40A |
50A |
65A |
80A |
Liquid viscosity |
1~500 mPa・s (Special 1~30,000 mPa・s) |
||||
Liquid temperature |
0~80℃ |
||||
Liquid pressure |
0.5MPa or under |
||||
Measuring accuracy |
Within ±0.5% |
||||
Standard connection |
IDF/ISO connection Ferrule,Screw |
||||
1S |
11/2S |
2S |
21/2S |
3S |
|
Material |
Main body:SCS13,SCS14,Rotor:PPS,GC |
||||
SCS13,SCS14:Stainless steel casting, PPS: Special plastic, GC: Carbon |
Specifications of counter unit
Nominal size symbol |
025 |
040 |
050 |
065 |
080 |
|||
Types |
Pointer type(A0),Zero resettable register type(Z8), Large-size drum counter type(V0),Printer zero resettable register type(P0),Electronic type(E0) |
|||||||
Indication |
Pointer type (A0) |
Pointer Dial plate |
Dial unit |
0.1 L |
1 L |
|||
Volume per rev. |
10 L |
100 L |
||||||
Total counter |
Dial unit |
10 L |
100 L |
|||||
Number of digits |
6 ( 999,999 x 10L ) |
6 ( 999,999 x 100L ) |
||||||
Zero resettable register type (Z8) |
Zero-reset counter |
Dial unit |
0.1 L |
1 L |
||||
Number of digits |
4 ( 9,999 L ) |
4 ( 9,999 x 10L ) |
||||||
Continuous total counter |
Dial unit |
1 L |
10 L |
|||||
Number of digits |
7 ( 9,999,999 L ) |
7 ( 9,999,999 x 10L ) |
||||||
Large-size drum counter type (V0) |
Zero-reset counter |
Dial unit |
- |
1 L |
||||
Number of digits |
- |
5 ( 99,999 L ) |
||||||
Continuous total counter |
Dial unit |
- |
1 L |
|||||
Number of digits |
- |
8 ( 99,999,999 L ) |
||||||
Printer zero resettable register type (P0) |
Zero-reset counter |
Dial unit |
- |
1 L |
||||
Number of digits |
- |
5 ( 99,999 L ) |
||||||
Continuous total counter |
Dial unit |
- |
1 L |
|||||
Number of digits |
- |
8 ( 99,999,999 L ) |
||||||
Electronic type (E0) |
Un totalized |
Nominal size symbol |
025 |
040 |
050 |
065 |
080 |
||||
Output |
Pulse output |
Unit pulse (A0,Z8,V0, P0) |
Type of signal |
(Note) Either one of (1) voltage no-contact signal (high frequency type, photoelectric type), or (2) reed switch contact signal. |
|||||
Output unit |
No-contact pulse output: See "No-contact pulse output" table. |
||||||||
Contact pulse output: See "Contact pulse output" table. |
|||||||||
Unitless pulse (E0) |
Type of signal |
Voltage no-contact output or open collector output Voltage no-contact: Signal level H: Approx. equal to voltage of external power (at no load) L:0.5V or less (at no load) Output resistance : Approx. 2.3kΩ Amplifier box FSES is including. |
Open collector: Voltage & current:27V DC, 30mA Voltage at ON:0.5V or less |
||||||
Cable between the flowmeter - amplifier box. Length:3m |
|
|
|||||||
Unit ※1 |
21.8mL |
46.0mL |
123.8mL |
123.8mL |
275.5mL |
||||
Pulse width |
Approx. 3.5msec |
||||||||
Analogue output |
Direct output impossible (DA converter required outside) |
||||||||
Power source |
Unit pulse (A0,Z8,V0,P0) |
The following external power sources are required, for outputting voltage no-contact signals: (1) High frequency type pulse generator: 6~26.4VDC , 23mA(at 24V DC) ,17 mA(at 12V DC) (2) Photoelectric type pulse generator: 12VDC, 50mA |
|||||||
Unitless pulse (E0) |
Voltage no-contact: DC12~24V 、 20mA(at 24V DC) 25mA(at 12V DC) Open collector: DC12~24V、12mA |
||||||||
Ambient temperature |
-10~60℃ |
||||||||
Material |
Aluminum die casting Electric counter (Type E0) has only signal output part. |
※1 Output pulse unit of unitless pulse shows nominal value output from this meter.
Output pulse unit table (Optional)
No-contact output pulse unit table (● Photoelectric type, ○: High frequency type,
Nominal size symbol |
One rev. of pointer |
Pulse unit |
|||||
1mL/P |
10mL/P |
100mL/P |
1L/P |
10L/P |
100L/P |
||
025 |
10L |
● |
○ |
○ |
○ |
― |
― |
040 |
10L |
― |
● |
○ |
○ |
― |
― |
050 |
100L |
― |
● |
○ |
○ |
○ |
― |
065 |
100L |
― |
● |
○ |
○ |
○ |
― |
080 |
100L |
― |
● |
○ |
○ |
○ |
― |
Contact output pulse unit table (○:Reed switch)
Nominal size symbol |
One rev. of pointer |
Pulse unit |
|||||
1mL/P |
10mL/P |
100mL/P |
1L/P |
10L/P |
100L/P |
||
025 |
10L |
― |
― |
― |
○ |
○ |
― |
040 |
10L |
― |
― |
― |
○ |
○ |
― |
050 |
100L |
― |
― |
― |
― |
○ |
○ |
065 |
100L |
― |
― |
― |
― |
○ |
○ |
080 |
100L |
― |
― |
― |
― |
○ |
○ |
High frequency pulse generator (Symbol:M)
Photoelectric pulse generator (Symbol:K)
Reed switch pulse generator (Symbol:R)
Type |
Output signal |
Max. voltage |
Max. current |
Switch capacity |
Contact resistance |
Max. generated pulse |
DRR-5 |
No-voltage contact pulse |
200V AC・DC |
1A |
25W |
0.06Ω |
5P/s |
MR506 |
No-voltage contact pulse |
50V DC |
250mA |
15W |
0.1Ω |
5P/s |
Pointer type(A0)、Zero resettable register type(Z8)、Electronic type(E0)
Nominal size symbol |
Working conditions |
1mPa・s~ |
4mPa・s~ |
10mPa・s~ |
50~500mPa・s |
025 |
Continuous |
500 ~ 2,500 |
350 ~ 3,500 |
200 ~ 3,500 |
170 ~ 3,500 |
Intermitten |
500 ~ 3,500 |
350 ~ 5,000 |
200 ~ 5,000 |
170 ~ 5,000 |
|
040 |
Continuous |
1,200 ~ 6,000 |
650 ~ 8,400 |
500 ~ 8,400 |
360 ~ 8,400 |
Intermitten |
1,200 ~ 8,500 |
650 ~ 12,000 |
500 ~ 12,000 |
360 ~ 12,000 |
|
050 |
Continuous |
2,400 ~ 12,000 |
1,200 ~ 17,000 |
1,000 ~ 17,000 |
750 ~ 17,000 |
Intermitten |
2,400 ~ 17,000 |
1,200 ~ 24,000 |
1,000 ~ 24,000 |
750 ~ 24,000 |
|
065 |
Continuous |
2,400 ~ 12,000 |
1,200 ~ 17,000 |
1,000 ~ 17,000 |
750 ~ 17,000 |
Intermitten |
2,400 ~ 17,000 |
1,200 ~ 24,000 |
1,000 ~ 24,000 |
750 ~ 24,000 |
|
080 |
Continuous |
5,000 ~ 25,000 |
2,500 ~ 35,000 |
2,000 ~ 35,000 |
1,500 ~ 35,000 |
Intermitten |
5,000 ~ 35,000 |
2,500 ~ 50,000 |
2,000 ~ 50,000 |
1,500 ~ 50,000 |
Large-size drum counter type(V0)
Nominal size symbol |
Working conditions |
1mPa・s~ |
4mPa・s~ |
10mPa・s~ |
50~500mPa・s |
040 |
Continuous |
1,800 ~ 6,000 |
1,600 ~ 8,400 |
1,200 ~ 8,400 |
900 ~ 8,400 |
Intermitten |
1,800 ~ 8,500 |
1,600 ~ 10,000 |
1,200 ~ 10,000 |
900 ~ 10,000 |
|
050 |
Continuous |
3,600 ~ 12,000 |
3,200 ~ 17,000 |
2,400 ~ 17,000 |
1,800 ~ 17,000 |
Intermitten |
3,600 ~ 17,000 |
3,200 ~ 20,000 |
2,400 ~ 20,000 |
1,800 ~ 20,000 |
|
065 |
Continuous |
3,600 ~ 12,000 |
3,200 ~ 17,000 |
2,400 ~ 17,000 |
1,800 ~ 17,000 |
Intermitten |
3,600 ~ 17,000 |
3,200 ~ 20,000 |
2,400 ~ 20,000 |
1,800 ~ 20,000 |
|
080 |
Continuous |
8,000 ~ 25,000 |
6,400 ~ 35,000 |
4,800 ~ 35,000 |
3,600 ~ 35,000 |
Intermitten |
8,000 ~ 35,000 |
6,400 ~ 40,000 |
4,800 ~ 40,000 |
3,600 ~ 40,000 |
Printer zero resettable register type(P0)
Nominal size symbol |
Working conditions |
1mPa・s~ |
4mPa・s~ |
10mPa・s~ |
50~500mPa・s |
040 |
Continuous |
3,600 ~ 6,000 |
3,200 ~ 8,400 |
2,400 ~ 8,400 |
1,800 ~ 8,400 |
Intermitten |
3,600 ~ 8,500 |
3,200 ~ 10,000 |
2,400 ~ 10,000 |
1,800 ~ 10,000 |
|
050 |
Continuous |
7,200 ~ 12,000 |
6,400 ~ 17,000 |
4,800 ~ 17,000 |
3,600 ~ 17,000 |
Intermitten |
7,200 ~ 17,000 |
6,400 ~ 20,000 |
4,800 ~ 20,000 |
3,600 ~ 20,000 |
|
065 |
Continuous |
7,200 ~ 12,000 |
6,400 ~ 17,000 |
4,800 ~ 17,000 |
3,600 ~ 17,000 |
Intermitten |
7,200 ~ 17,000 |
6,400 ~ 20,000 |
4,800 ~ 20,000 |
3,600 ~ 20,000 |
|
080 |
Continuous |
16,000 ~ 25,000 |
13,000 ~ 35,000 |
9,600 ~ 35,000 |
7,200 ~ 35,000 |
Intermitten |
16,000 ~ 35,000 |
13,000 ~ 40,000 |
9,600 ~ 40,000 |
7,200 ~ 40,000 |
(Note) 1. "Continuous" refers to a case where the daily operating time exceeds 8 hours, while "Intermittent" expresses a case where the daily operating time is no more than 8 hours.
Nominal size symbol |
Flow rate 100% |
025 |
5,000L/h |
040 |
12,000L/h |
050 065 |
24,000L/h |
080 |
50,000Lh |
Nominal size symbol |
IDF/ISO |
|
Ferrule |
Screw |
|
025 |
190 |
190 |
040 |
210 |
210 |
050 |
270 |
270 |
065 |
270 |
270 |
080 |
340 |
340 |
(Unit:mm)
Pointer type(A0)、Zero resettable register type(Z8)、Large-size drum counter type(V0)、 Printer zero resettable register type(P0
Electronic type(E0)
Nominal size symbol |
Nominal size |
Connection symbol |
L |
A |
B |
E |
F |
K |
W |
S |
m |
n |
d |
Weight kg |
025 |
25 |
D |
190 |
109 |
51 |
96 |
167 |
170 |
140 |
70 |
60 |
30 |
9 |
7.5 |
H |
||||||||||||||
040 |
40 |
D |
210 |
155 |
77 |
135 |
172 |
210 |
204 |
96 |
90 |
37 |
12 |
17 |
H |
||||||||||||||
050 |
50 |
D |
270 |
211 |
115 |
169 |
177 |
275 |
262 |
160 |
120 |
42 |
12 |
26 |
H |
||||||||||||||
065 |
65 |
D |
270 |
211 |
115 |
169 |
177 |
275 |
262 |
160 |
120 |
42 |
12 |
27 |
H |
||||||||||||||
080 |
80 |
D |
340 |
249 |
130 |
239 |
178 |
295 |
328 |
240 |
130 |
26 |
18 |
54 |
H |
Pulse generator type
Nominal size symbol |
Nominal size |
Connection symbol |
L |
A |
B |
E |
F |
K |
W |
S |
m |
n |
d |
Weight kg |
025 |
25 |
D |
190 |
109 |
51 |
96 |
242 |
170 |
140 |
70 |
60 |
30 |
9 |
9.5 |
H |
||||||||||||||
040 |
40 |
D |
210 |
155 |
77 |
135 |
247 |
210 |
204 |
96 |
90 |
37 |
12 |
19 |
H |
||||||||||||||
050 |
50 |
D |
270 |
211 |
115 |
169 |
252 |
275 |
262 |
160 |
120 |
42 |
12 |
28 |
H |
||||||||||||||
065 |
65 |
D |
270 |
211 |
115 |
169 |
252 |
275 |
262 |
160 |
120 |
42 |
12 |
29 |
H |
||||||||||||||
080 |
80 |
D |
340 |
249 |
130 |
239 |
253 |
295 |
328 |
240 |
130 |
26 |
18 |
56 |
H |
Large-size drum counter type(V0
Nominal size symbol |
Nominal size |
Connection symbol |
L |
A |
B |
E |
F |
W |
S |
m |
n |
d |
Weight kg |
040 |
40 |
D |
210 |
354 |
77 |
135 |
202 |
204 |
96 |
140 |
92 |
12 |
26 |
H |
|||||||||||||
050 |
50 |
D |
270 |
381 |
115 |
169 |
207 |
262 |
160 |
170 |
97 |
12 |
35 |
H |
|||||||||||||
065 |
65 |
D |
270 |
381 |
115 |
169 |
207 |
262 |
160 |
170 |
97 |
12 |
36 |
H |
|||||||||||||
080 |
80 |
D |
340 |
386 |
130 |
239 |
209 |
328 |
240 |
170 |
66 |
18 |
63 |
H |
Printer zero resettable register type(P0)
Pulse generator type
Printer zero resettable register type(P0
Nominal size symbol |
Nominal size |
Connection symbol |
L |
A |
B |
E |
F |
W |
S |
m |
n |
d |
Weight kg |
040 |
40 |
D |
210 |
444 |
77 |
135 |
202 |
204 |
96 |
140 |
92 |
12 |
34 |
H |
|||||||||||||
050 |
50 |
D |
270 |
471 |
115 |
169 |
207 |
262 |
160 |
170 |
97 |
12 |
43 |
H |
|||||||||||||
065 |
65 |
D |
270 |
471 |
115 |
169 |
207 |
262 |
160 |
170 |
97 |
12 |
44 |
H |
|||||||||||||
080 |
80 |
D |
340 |
476 |
130 |
239 |
209 |
328 |
240 |
170 |
66 |
18 |
71 |
H |
Nominal size symbol |
Nominal size |
Connection symbol |
L |
A |
B |
E |
W |
S |
m |
n |
d |
Weight kg |
025 |
25 |
D |
190 |
109 |
51 |
96 |
140 |
70 |
60 |
30 |
9 |
4 |
H |
||||||||||||
040 |
40 |
D |
210 |
155 |
77 |
135 |
204 |
96 |
90 |
37 |
12 |
13 |
H |
||||||||||||
050 |
50 |
D |
270 |
211 |
115 |
169 |
262 |
160 |
120 |
42 |
12 |
22 |
H |
||||||||||||
065 |
65 |
D |
270 |
211 |
115 |
169 |
262 |
160 |
120 |
42 |
12 |
23 |
H |
||||||||||||
080 |
80 |
D |
340 |
249 |
130 |
239 |
328 |
240 |
130 |
26 |
18 |
50 |
H |
Type |
Specification code |
Specifications |
025 |
040 |
050 |
065 |
080 |
||||
FS |
|
Food flow meter |
● |
● |
● |
● |
● |
||||
Counter symbol |
A0 |
|
Pointer and direct-reading type |
● |
● |
● |
● |
● |
|||
Z8 |
|
Zero resettable register type |
○ |
○ |
○ |
○ |
○ |
||||
V0 |
|
Large-size drum counter type |
× |
○ |
○ |
○ |
○ |
||||
P0 |
|
Printer zero resettable register type |
× |
○ |
○ |
○ |
○ |
||||
E0 |
|
Electronic type |
○ |
○ |
○ |
○ |
○ |
||||
Nominal size symbol |
025 |
|
Nominal size: 25A |
For the max. flow rate, refer to "Flow Rate Range Table" |
● |
|
|
|
|
||
040 |
|
Nominal size: 40A |
|
● |
|
|
|
||||
050 |
|
Nominal size: 50A |
|
|
● |
|
|
||||
065 |
|
Nominal size: 65A |
|
|
|
● |
|
||||
080 |
|
Nominal size: 80A |
|
|
|
|
● |
||||
Type of generator and pulse unit |
12 |
|
Without pulse output |
● |
● |
● |
● |
● |
|||
R4 |
|
Reed switch (contact) pulse 1L/p |
○ |
○ |
× |
× |
× |
||||
R5 |
|
Reed switch (contact) pulse 10L/p |
○ |
○ |
○ |
○ |
○ |
||||
R6 |
|
Reed switch (contact) pulse 100L/p |
× |
× |
○ |
○ |
○ |
||||
RX |
|
Reed switch (contact) pulse Other than above |
○ |
○ |
○ |
○ |
○ |
||||
M2 |
|
High frequency (no-contact) pulse 0.01L/p |
○ |
× |
× |
× |
× |
||||
M3 |
|
High frequency (no-contact) pulse 0.1L/p |
○ |
○ |
○ |
○ |
○ |
||||
M4 |
|
High frequency (no-contact) pulse 1L/p |
○ |
○ |
○ |
○ |
○ |
||||
M5 |
|
High frequency (no-contact) pulse 10L/p |
× |
× |
○ |
○ |
○ |
||||
MD |
|
High frequency (no-contact) pulse DA conversion pulse |
○ |
○ |
○ |
○ |
○ |
||||
MX |
|
High frequency (no-contact) pulse Other than above |
○ |
○ |
○ |
○ |
○ |
||||
K1 |
|
Photoelectric (no-contact) pulse 0.001L/p |
○ |
× |
× |
× |
× |
||||
K2 |
|
Photoelectric (no-contact) pulse 0.01L/p |
× |
○ |
○ |
○ |
○ |
||||
KX |
|
Photoelectric (no-contact) pulse Other than above |
○ |
○ |
○ |
○ |
○ |
||||
XX |
|
Electric counter( Voltage no-contact output or open collector output)pulse |
○ |
○ |
○ |
○ |
○ |
||||
Connection symbol |
D |
IDF/ISO Screw |
● |
● |
● |
● |
● |
||||
H |
IDF/ISO Ferrule |
● |
● |
● |
● |
● |
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Mollitia iste laborum ad impedit pariatur esse optio tempora sint ullam autem deleniti nam in quos qui nemo ipsum numquam, reiciendis maiores quidem aperiam, rerum vel recusandae