  • Comprehensive Safety Integration:

    • Combines overfill prevention, static grounding, and vehicle identification into a single unit for maximum safety during loading.
  • Dynacheck® Dynamic Self-Checking® Circuitry:

    • Continuously monitors all critical components (control unit, wiring, and sensors) to ensure operational integrity.
    • In case of a fault, it triggers a loading shutdown to prevent overfill.
  • Proven Reliability:

    • Over 15 years of field performance, making it the top choice worldwide for loading rack safety systems.
  • Sensor and Vehicle Monitoring:

    • Automatically detects both two-wire optic/thermistor and five-wire optic vehicle sensors.
    • Monitors up to 8 two-wire or 15 five-wire vehicle sensors.
  • Comprehensive Diagnostic Display:

    • Provides a visual diagnostic of overfill sensor status and vehicle static grounding conditions.
    • Will not allow loading if a fault or wet sensor condition is detected.
  • Vehicle Identification Module:

    • Reads the truck-mounted T.I.M.® module and vehicle data, ensuring loading can be restricted based on criteria set by the terminal (e.g., insurance, certifications, billing).
  • Compatibility with Other Systems:

    • Works seamlessly with Scully Intellicheck® and load-anywhere on-board systems.
  • Durable Connection:

    • Easy-to-install and rugged high-impact Scully plug and cable units (sold separately) for vehicle connection.

The ordering information below is for Intellitrol FM and FMC approved units. For International ATEX and SIL approved models see:

for UK Market

67274_Intellitrol Rev B_ATEX_UK.pdf

for Europe & Other Countries requiring ATEX approval:

67274_Intellitrol Rev B_ATEX_BE_SIL.pdf
67274_Intellitrol Rev B_ATEX_BE.pdf

CONTROL UNITS
Part Number** Model Number Description Approvals*
09549 IC2-OG Intellitrol Overfill Prevention & Ground Verification FM/CSA
09550 IC2-OGV Intellitrol Overfill, Ground Verification and V.I.P. FM & CSA
09547 ICC2-OG Intellitrol Overfill Prevention & Ground Verification ATEX
09548 ICC2-OGV Intellitrol Overfill, Ground Verification and V.I.P. ATEX

*Factory Mutual and Factory Mutual Canada Intrinsic Safety Approvals for Hazardous Environments. For more approval information see the Technical Specs tab for this product.

SYSTEM ACCESSORIES
Part Number Description
08939 Security Bypass Authorizer
08863 Deadman Control Switch Assembly
08951 Intelliview® 2 Terminal Software
09001 USB to RS-485 Converter Kit (for communications)
08958NV SC-8OB Sculcon Junction Box with 8B Style Black Poly Plug and 6 meter (20 ft) Blue Straight Cable (for 2-wire or 5-wire sensors – 4-bayonet pins – 10 contact pins)
08959NV SC-6W Sculcon Junction Box with 6W Style Blue Poly Plug and 9 meter (30 ft) Blue Coiled Cable (for 5-wire sensors – 3 bayonet pins – 6 contact pins)
09146NV SC-8OB Sculcon Junction Box with 8B Style Black Poly Plug and 6 meter (30 ft) Blue Coiled Cable (for 2-wire or 5-wire sensors – 4-bayonet pins – 10 contact pins)
27326 Cable,10 Conductor, Blue Straight,.71 Outer Dimension
REPLACEMENT PARTS
Part Number Description
09551 Module Assembly, 2-OG 240V
09552 Module Assembly, 2-OGV 120V
09577 Module Assembly, 2-OGV 240V
09576 Module Assembly, 2-OG 120V
50005 Cover Bolt, M8 x 1.25 x 25mm
26372 Contact Fuse (F5, F8), 5A, Hi-interrupt
31340 Cover O-ring (gasket)
40268 Corrosion Inhibitor
09181 (ATEX) Lens Assembly (with 6 mounting screws)
08980 (FM) Lens Assembly (with 6 mounting screws)
09553 Lens Assembly (with 6 mounting screws)
08982 Display Cable Feed-through
50080 Lens Mounting Screw, 8-32 x 3/4
54039 Retaining Ring, Cover Hinge
38052* Text Mask (English), Overll and Ground
38053* Text Mask (English), Overll, Ground and Vehicle ID
09481 Heat Sink Assembly

 

The specification provided seems to describe an industrial overfill prevention system, likely used in hazardous locations for managing fluid transfer operations, such as in tank trucks or storage tanks. Below is a breakdown of the key points from the specification:

Temperature Range:

  • Operating IC models: -40°F to +140°F (-40°C to +60°C).
  • Storage: -50°F to +185°F (-45°C to +85°C).

Power Requirements:

  • Voltage: 100 – 130 VAC (120 VAC setting) or 200 – 250 VAC (240 VAC setting).
  • Frequency: 50/60 Hz.
  • Maximum Power Consumption: 30 watts.

Enclosure:

  • Type: Explosion-proof and weathertight housing.
  • Material: Powder-coated, corrosion-resistant finish.
  • Weather Rating: Type 4X (outdoor) and IP65 (dust-tight and water-resistant).

Approvals:

  • Hazardous Locations: FM and FMC approvals for use in Class I, Division 1, Group C and D hazardous locations.
  • Enclosure Rating: Type 4X (explosion-proof, suitable for outdoor use).

Dimensions:

  • Refer to Intellitrol FM data sheet #67247 for detailed dimensions.

Sensor Inputs:

  • Supported Sensors:
    • Up to 8 Scully two-wire optic/thermistor sensors (6 or 8 channels).
    • Up to 15 five-wire optic sensors (maximum).
    • Automatic detection of two-wire vs. five-wire sensors.
    • Three-wire, high-temperature thermistor sensors are not supported.

Ground Verification Inputs:

  • Ground Bolt Detection: Requires a Scully ground bolt connected to pin 9 of the overfill prevention system socket, installed according to Scully installation instructions.
  • Resistive Ground Detection: Requires vehicles to be wired with pins 9 and 10 connected to separate chassis points.

Deadman Input:

  • Provides an intrinsically safe input for an optional deadman switch.

Outputs:

  • Main Permissive Output:
    • Form-A (“normally open”) AC relay output with monitored redundant contacts.
    • Closes when all conditions (dry sensors, proper ground connection, etc.) are met.
    • Rated for 250 VAC, 5 amps resistive. This output is used for product flow shutdown.
  • Main Form-C, Volt-Free Output Relay:
    • Form-C (“normally open” and “normally closed”) volt-free redundant relay output.
    • The relay contacts reverse state when conditions are met.
    • Rated for 250 VAC, 5 amps resistive.
    • The "normally open" contact can be used for product flow shutdown, and the "normally closed" contact is for non-critical output status reporting.

Response Time:

  • Maximum of 450 milliseconds after a wet sensor or fault condition.

Communications Port:

  • Type: Half-duplex, RS-485 multi-drop communications port.
  • Protocol: Modbus™ RTU (straight binary).
  • Baud Rate: 1200, 2400, 4800, 9600, or 19200 baud.
  • Data Bits: 8 bits.
  • Parity: Even, odd, or no parity.

Shipping Weight:

  • 31 lbs. (14.1 kg).

Overfill Prevention:

  • Automatic Sensor Detection:

    • Automatically detects whether the vehicle is equipped with two-wire optic/thermistor or five-wire optic sensors.
    • Supports up to 8 two-wire or 15 five-wire sensors for monitoring vehicle compartments.
  • Dynacheck Continuous Self-Checking Circuitry:

    • Provides continuous monitoring of the system’s health and performance.
    • Checks the controller, wiring, connections, and sensors 30 times per second to ensure everything is functioning correctly.
    • Dynacheck ensures maximum safety by detecting faults promptly and initiating system shutdown when necessary.
  • Immediate Shutdown for Overfill/Fault:

    • Automatic shut-off of product flow occurs in less than half a second when overfill or fault conditions are detected.
    • The system is capable of shutting down the flow by controlling valves or pumps.
  • Redundant Output Relays:

    • Provides redundant main output relays for fail-safe operation.
    • The system continuously monitors these relays' contacts to ensure proper operation, adding another layer of reliability.

Dynacheck Safety:

  • Continuous Monitoring:

    • Pulsed signals are used to constantly check the integrity of the entire system, including the controller, wiring, connections, and sensors.
    • If a sensor comes in contact with liquid or if a system fault occurs, the pulsed signals cease, and the controller immediately triggers a shutdown of the loading operation.
  • Automatic Shutdown:

    • The system sends a signal to automatically shut down the operation if a fault is detected, preventing overfill and ensuring safety.

Complete Diagnostics and Communication:

  • LED Indicators:

    • Red and Green LEDs display the main status of the system, indicating whether the system is permissive, non-permissive, or in bypass mode.
    • These indicators help operators easily assess the system's operational status at a glance.
  • Wet Sensor Detection and Fault Indication:

    • The system provides individual wet sensor detection for each compartment, helping identify which sensor is in contact with liquid.
    • It also displays sensor and wiring faults, offering immediate visibility of any issues for quick troubleshooting.
  • Communication Capabilities:

    • The system can communicate with Scully’s Intelliview™ software (a Microsoft Windows®-based application) or integrate with other terminal automation systems.
    • This allows for detailed diagnostics, real-time monitoring, and system management from a central location.

Vehicle Ground Verification:

  • Self-Checking Ground Verification:

    • The system performs self-checking ground verification to ensure that a proper ground connection is in place, which is crucial for static discharge prevention during loading operations.
    • This check is performed with a single connection using the overfill prevention plug and cable, simplifying the setup and installation.
  • No Separate Grounding Controller Required:

    • There is no need to purchase or install a separate grounding controller. The overfill prevention system incorporates this function, reducing both cost and complexity.
  • Automatic Shutdown for Improper Ground:

    • If the system detects that a proper ground bond is not established, it automatically prevents and shuts down the loading operation to avoid hazardous static discharge, ensuring safety.
  • Flexible Grounding Configuration:

    • The system can be configured for two types of ground verification:
      • Scully Ground Bolt: A ground bolt mounted to the vehicle chassis for detecting a proper ground connection.
      • Resistive Ground Detection: This method requires separate wiring for pin 9 and pin 10, providing additional flexibility in how vehicles are grounded for different scenarios.

Vehicle Identification:

  • Automatic Vehicle ID Detection:

    • The system can automatically read the unique vehicle identification number (VIN) from a Scully vehicle-mounted I.D. module when the overfill prevention plug is connected to the vehicle.
  • Communication of Vehicle ID to Terminal:

    • Once the ID is detected, the system communicates the vehicle's identification number to the terminal’s PC, loading controller, or terminal automation system for immediate verification.
  • Prevents Unauthorized Loading:

    • If the vehicle fails to meet the terminal’s authorization requirements, the system automatically prevents loading from occurring. This ensures that only authorized vehicles are allowed to load at the terminal.
  • Automatic Verification of Vehicle Information:

    • By comparing the vehicle’s unique identification number to the terminal automation system’s re-programmed database, the system can automatically verify:
      • Vapor-tightness certification
      • Contract and insurance status
      • Number of compartments on the vehicle
      • Other vehicle-specific information.
  • Streamlined Documentation and Inspection:

    • This system eliminates the need for manual documentation review and inspection, saving time and reducing the risk of human error. Information is automatically verified, ensuring that only vehicles that meet safety and regulatory standards are loaded.

Summary of Optional Features:

  1. Vehicle Ground Verification:
    • Self-checking ground verification with a single connection.
    • No separate grounding controller needed.
    • Automatic shutdown if proper bonding for static discharge is not detected.
    • Configurable for either Scully Ground Bolt or resistive ground detection.
  2. Vehicle Identification:
    • Automatically reads the vehicle ID from the mounted I.D. module.
    • Communicates the vehicle ID to the terminal system for verification.
    • Prevents loading if the vehicle is not authorized or fails to meet terminal requirements.
    • Automatically verifies vehicle information (e.g., vapor-tightness, contract, insurance).
    • Reduces the time and cost associated with manual documentation and inspection.