The VEGA FIBERTRAC 31 is a radiometric sensor designed for continuous measurement of liquids and bulk solids.
Returns & Refunds Policy
Warranty Against Defects
Original Products
Ships Worldwide
Dedicate Support
The VEGA FIBERTRAC 31 is a radiometric sensor designed for continuous measurement of liquids and bulk solids. It utilizes a flexible plastic sensing element, making it adaptable for use in a wide range of industrial applications, particularly those involving aggressive products, extreme process temperatures, or challenging measurement conditions.
The FIBERTRAC 31 works based on radiometric measurement principles, using gamma rays emitted by a Caesium-137 or Cobalt-60 isotope. The emitted radiation passes through the material (liquid or solid) being measured, and a detector on the opposite side captures the attenuated radiation. The attenuation is directly related to the material's level, density, and mass flow rate, providing accurate measurements.
Available in two versions:
The VEGA FIBERTRAC 31 is globally approved for use in hazardous areas, marine environments, and hygienic applications. Specific safety instructions apply based on the approval type (e.g., Ex approval).
This sensor is well-suited for industries that require robust, precise, and cost-effective level measurement in complex process environments.
Measuring range |
1 … 7 m (3.28 … 22.97 ft) |
Non-repeatability |
±0.5 % at -20 °C … +50 °C (-4 °F … +122 °F) |
Ambient temperature |
-20 °C … +50 °C (-4 °F … +122 °F) Extended range available |
Voltage supply
Operating voltage |
20 … 72 V DC; 20 … 253 V AC, 50/60 Hz |
Max. power consumption |
4 W; 6 VA |
Analogue input
Input type |
4 … 20 mA passive |
Internal load |
250 Ω |
Switching input
Input type |
|
Ʋ Open Collector |
10 mA |
Ʋ Relay contact |
100 mA |
Relay output
Switching voltage |
max. 253 V AC/DC |
Switching current |
max. 3 A AC (cos phi > 0.9), 1 A DC |
Breaking capacity |
min. 50 mW, max. 750 VA AC, 40 W DC (with U < 40 V DC) |
Current output
Range |
4 … 20 mA/HART, active or passive |
Max. load |
500 Ω (300 Ω with intrinsically safe IS) |
Switching output
Type of output |
NPN transistor output (floating) |
Switching voltage |
< 55 V DC |
Load current |
< 400 mA |
General data
Weight |
max. 9.2 kg (20.3 lbs) + 1.22 kg/m (0.82 lbs/ft) |
SIL qualification |
Optionally up to SIL2 |
Two connection chambers are available depending on the instrument version, the signal output is either in the primary or in the secondary chamber.
Primary terminal connections
Secondary terminal connections (intrinsically safe devices)
Lorem ipsum dolor sit amet, consectetur adipisicing elit. Mollitia iste laborum ad impedit pariatur esse optio tempora sint ullam autem deleniti nam in quos qui nemo ipsum numquam, reiciendis maiores quidem aperiam, rerum vel recusandae